16 March 2020 Adaptively variable frame-rate fluoroscopy with an ultra-fast digital x-ray tube based on carbon nanotube field electron emitters
Author Affiliations +
Abstract
Fluoroscopy is a radiological technique that provides real-time x-ray viewing in interventional and angiographic procedures. In fluoroscopic procedures, there are several issues have to be solved, such as a risk of radiation exposure to the patients and operators and low image qualities by motion blur. To lower the radiation dose and motion blur, most of fluoroscopic systems provide a pulse-mode operation. However, conventional systems adopt filament-based thermionic analog x-ray tubes that generate relatively longer x-ray pulses than a few milliseconds due to intrinsic difficulty in modulating electron emissions, thus still have many problems of motion blur for fast objects, unnecessary x-ray radiation, and mismatched frame rate to the moving objects. In this work, we tried to solve these problems by suggesting an adaptively variable frame-rate fluoroscopy with an ultra-fast digital x-ray tube (DXT) based on carbon nanotube (CNT) field electron emitters.

We first fabricated a vacuum-sealed CNT DXT and its monoblock with a power generator for the fluoroscopic system. Ultra-short and high-frequency x-ray pulses of up to 500 ns at 1 MHz was achieved by the direct control of electron emission through an active current-control unit. X-ray pulse frames from the CNT DXT with a tube voltage of 120 kV and current of 20 mA were adaptively modulated in the range of 1-30 Hz according to the motion of objects, greatly improving temporal resolution with a reduced radiation dose. The adaptively variable frame-rate fluoroscopy could pave the way for both reducing x-ray doses and improving temporal and spatial resolution.
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jeong-Woong Lee, Jin-Woo Jeong, Sora Park, Jae-Woo Kim, Jun-Tae Kang, Ki Nam Yun, Eunsol Go, Hyojin Jeon, Yujung Ahn, Ji-Hwan Yeon, Sunghee Kim, and Yoon-Ho Song "Adaptively variable frame-rate fluoroscopy with an ultra-fast digital x-ray tube based on carbon nanotube field electron emitters", Proc. SPIE 11312, Medical Imaging 2020: Physics of Medical Imaging, 113123F (16 March 2020); https://doi.org/10.1117/12.2549814
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Fluoroscopy

Carbon nanotubes

X-ray imaging

Temporal resolution

RELATED CONTENT

Development of 120 kV CNT based digital x ray tube...
Proceedings of SPIE (April 04 2022)
Seventh-generation CT
Proceedings of SPIE (March 31 2016)
X ray tube based on carbon nanotube field emitter for...
Proceedings of SPIE (February 15 2021)
Wide-aperture x-ray image converter tubes
Proceedings of SPIE (January 01 1991)
A dynamic micro CT scanner with a stationary mouse bed...
Proceedings of SPIE (March 13 2009)

Back to Top