Abstract
We have developed a high precision fusion splicer, which can instantly splice a 12-fiber ribbon at the maximum. By automatic inspection on a fiber ribbon at the stage of pre/post splicing, a estimated splice loss can be inferred through calculation. In the case of splicing a 12-fiber ribbon, the resultant splice losses averaged 0.03 dB, while 2 min. were required for splicing.
© (1992) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Hideki Watanabe, Yasukazu Toimoto, and Keiji Oda "Fiber fusion splicer for 12-fiber ribbon", Proc. SPIE 1817, Optical Communications, (28 October 1992); https://doi.org/10.1117/12.131345