Paper
24 September 1999 Spatial calibration of the EO-1 Advanced Land Imager
Author Affiliations +
Abstract
Spatial calibrations have been performed on the Advanced Land Imager (ALI) of the EO-1 satellite. Topics discussed in this paper include end-to-end imaging test, measurements of system modulation transfer function (MTF), and pixel lines of sight. The MTF measurements were made by recording scans of a knife-edge past the pixels. The techniques used to place the focal plane at the correct focal position are described, since they make use of MTF measurements. Line-of- sight measurements combine theodolite measurements of the telescope distortions and the photolithographic patterns of the detector arrays with images of a stationary Ronchi ruling recorded with the instrument at its normal operating conditions in a thermal vacuum chamber.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
David R. Hearn, Jeffrey A. Mendenhall, and Berton C. Willard "Spatial calibration of the EO-1 Advanced Land Imager", Proc. SPIE 3750, Earth Observing Systems IV, (24 September 1999); https://doi.org/10.1117/12.363503
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Modulation transfer functions

Calibration

Collimators

Imaging systems

Telescopes

Staring arrays

Point spread functions

Back to Top