Paper
23 July 1985 Stepper Overlay Calibration Using Alignment To A Latent Image
Karl W. Edmark, Christopher P. Ausschnitt
Author Affiliations +
Abstract
We describe a method which minimizes the time required to set up and sustain optimum overlay performance of the DSW step-and-repeat system throughout a product wafer run. Improvement in both system performance and productivity is realized. Fundamental to the technique are the latent image formed by the exposure of photoresist, the AWA' global alignment system and the laser-metered stages of the DSW® system. We eliminate the need to develop wafers and to read verniers during the DSW® system set-up. Furthermore, we demonstrate the potential for on-the-fly calibration using product reticles and product wafers. The approach is generally applicable to the overlay calibration of optical exposure tools.
© (1985) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Karl W. Edmark and Christopher P. Ausschnitt "Stepper Overlay Calibration Using Alignment To A Latent Image", Proc. SPIE 0538, Optical Microlithography IV, (23 July 1985); https://doi.org/10.1117/12.947752
Lens.org Logo
CITATIONS
Cited by 6 scholarly publications and 14 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Reticles

Semiconducting wafers

Optical alignment

Calibration

Microscopes

Photoresist materials

Optical lithography

RELATED CONTENT

Fractured Alignment Mark Technology For Wafer Steppers
Proceedings of SPIE (August 20 1986)
Improvements in 0.5-micron production wafer steppers
Proceedings of SPIE (July 01 1991)
Recent Advances Of Optical Step-And-Repeat System
Proceedings of SPIE (June 20 1985)
Overlay Tolerances For Vlsi Using Wafer Steppers
Proceedings of SPIE (January 01 1988)
SMART SET An Integrated Approach to Stepper Set...
Proceedings of SPIE (January 02 1986)

Back to Top