1.IntroductionCellular-level observation of the ocular tissue structure of a living human eye has been challenging. In vivo cellular examination of the cornea was first demonstrated by a specular microscope that enabled the visualization of the corneal endothelium.1 In the 1980s, the corneal confocal microscope was developed for high-resolution corneal imaging ex vivo.2 The technological advances in confocal microscopes have since led to observation of living human eye at a subcellular level. 3, 4, 5, 6, 7, 8 Recently, optical coherence tomography (OCT) has emerged as a new technology for high-resolution, longitudinal cross-sectional imaging. OCT has been applied to retinal imaging, enabling the visualization of morphological structure of the retina as well as the assessment of retinal thickness.9 More recently, high-speed OCT techniques in the Fourier domain have been developed and applied to the imaging of the retina10, 11 and the anterior segment.12, 13 The axial resolution of OCT is governed by the bandwidth of the light source, and the transverse resolution is determined by the spot size of the incident beam. In standard OCT using a superluminescent diode as the light source, the axial resolution is . To provide a long field depth, a low numerical aperture (NA) objective is commonly used, limiting the transverse resolution to . To realize ultrahigh resolution for subcellular imaging, an OCT system using an ultra-broadband femtosecond laser and a high-NA objective has achieved an axial resolution of and a transverse resolution of .14 In an alternative form of OCT imaging, a horizontal cross-sectional (en face) image can be acquired by scanning the incident beam across the sample at a fixed depth.15 Such an en face OCT image is the familiar form of a confocal microscopic image. Recently, full-field OCT (FF-OCT) has been of increased interest as a nonscanning, high-resolution, en face OCT method. 16, 17, 18, 19, 20 In FF-OCT, the sample is illuminated with a parallel beam, and the signal light backscattered from the sample is detected by a detector array in a two-dimensional (2D) manner. Since an ultra-broadband thermal light source can be effectively employed for illuminating the sample, a high axial resolution of can be achieved. Meanwhile, the state-of-the-art, high-resolution sensor array, such as CCD or complementary metal oxide semiconductor (CMOS) camera, incorporated with a high-NA objective provides a high transverse resolution as well. Grieve have reported comprehensive results of ultrahigh-resolution FF-OCT imaging using excised cornea and retina in the mouse, rat, and pig.21, 22 However, imaging results of the human cornea have not been reported. In this work, we demonstrate subcellular cross-sectional imaging results of a donor cornea using ultrahigh-resolution FF-OCT implemented with a thermal light source and high-NA immersion objectives. Our FF-OCT system offers a two-times higher axial resolution than a corneal confocal microscope reported in the literature.8, 23, 24 To the best of our knowledge, we report the first subcellular imaging of a human donor cornea and the visualization of a 2D keratocyte network by FF-OCT. 2.Materials and MethodsA schematic of the FF-OCT system is shown in Fig. 1 . Our system is based on a white light interference microscope with a Linnik-type configuration. The system is similar to the one previously demonstrated in the literature.16, 19 The radiation from a tungsten halogen lamp is incident into a flexible fiber bundle and then directed to a Köhler illuminator (KI) system, in which a variable aperture stop and a field stop are assembled. By using the KI system associated with a fiber bundle, the tungsten halogen lamp can be placed away from an interferometer, so that any turbulence caused by a cooling fan housed in the halogen lamp power supply can be minimized. Output from the KI system is launched into the Michelson interferometer and split into the signal and reference beams by a 50:50 broadband beam splitter (BS). Two identical infinity-corrected water immersion objectives ( , 0.3-NA, UMPLFL 10XW; Olympus, Tokyo, Japan) with a working distance of are placed in both arms of the interferometer, respectively. The signal light is illuminated onto the sample by an objective, and the backscattered light is collected by the same objective and transferred to the BS. The reference light is reflected by the total reflection mirror and returned to the BS through the objective. A drop of water (W3500 tissue culture water; Sigma-Ardorich, St. Louis, MO) is put as an immersion fluid between the tip of the objective and the total reflection mirror. A neutral density (ND) filter whose density is optimized for corneal imaging is placed in the reference arm to increase the visibility of the interferometric image. To minimize dispersion mismatch between the signal and reference arms, a BK7 glass plate (GP) is placed in the reference arm, so that the dispersion in both arms is initially matched. The output light from the interferometer is detected by a microscope setup, where the interferometric image is captured by a silicon-based CCD camera (MC-512PF; Texas Instruments Japan). The CCD camera has pixels with a 12-bit resolution at a rate of . The aperture stop is placed at the exit of the interferometer to reject the unwanted back-scatterings from the optics (e.g., ND filter and GP) in the interferometer. The field of view of the FF-OCT system is determined by the magnification of the optical setup and the pixel size of the CCD. In this experiment, it is set to , with a pixel size of in an object space. To extract the interference component from the CCD output, we employ a conventional four-step phase shift detection technique, where four images detected at the phase shifts of 0, , , and are used for the linear operation. To increase the detection sensitivity, 10 images at each phase are continuously captured and averaged. As a result, 40 images are used to measure a single FF-OCT image, and the image acquisition time is approximately . Measurement is performed by a home-written software using the Microsoft Visual development environment, where an executable code is optimized for an Intel Pentium IV processor. The software sequence including image measurement, processing, display, and export to the disk is fully automated. FF-OCT images are displayed using a logarithmic lookup table in 256 grayscale image, where a high reflectance is displayed as white against the black background. Although a submicron-level ultrahigh axial resolution can be achieved by use of the extremely broad bandwidth of the halogen lamp, only a partial bandwidth in the near-infrared range of to has been chosen. Optical filters are inserted at the exit of the KI system to cut off both the visible and long-wavelength components. This wavelength region is selected because of the splitting ratio of the BS, where a transmittance and reflectance are evenly divided. The resultant spectrum, which is depicted in the inset of Fig. 1, has a quasi-Gaussian distribution centered at , with a bandwidth of . The incident power on the sample surface is approximately , which is well below the ANSI standard for maximum permissible ocular exposure. The sensitivity of our system is better than , which is lower than time-domain OCT and Fourier-domain OCT. An FF-OCT image is detected at a depth matched to the focal plane of the imaging system. By translating the sample using a precision stage (ALV-600-H0M; Chuo Precision Industrial, Tokyo, Japan) along the optical axis ( -), a stack of FF-OCT images at different depths is acquired. Using the three-dimensional (3D) data set, a longitudinal cross-section ( -, -) common to that of a conventional OCT or ultrasound biomicroscopy can be sectioned out for comparison study. Two human donor corneas from one subject (45 years old, 7 days’ postmortem) for experimental use were obtained as a corneoscleral button. There was no evidence that the donor had suffered from ophthalmological disease except that there were mild haze at the epithelium, scars at the superficial stroma, and a few folds in Descemet’s membrane. The corneas were immersed in Optisol GS (Bausch & Lomb Inc, Rochester, NY) and stored at for sample preservation. When proceeded to examination, the donor corneas were set into a small container filled with a cooled Hank’s balanced saline solution and the objective was then lowered to the cornea. The objective lens was sterilized with 70% isopropyl alcohol before examination. All investigations were performed in the central area of the cornea from the epithelial side to the endothelial side. No staining and no contrast agents were used. 3.ResultsFigure 2 shows a longitudinal cross section ( ) reconstructed from a stack of FF-OCT images at a depth interval. Figure 2 aims to provide, in the common form of a conventional OCT, an inspection of the ultrahigh sectioning capability of FF-OCT. It can be seen that the epithelium (EP), Bowman’s layer (BL), stroma (ST), Descemet’s membrane (DM), and endothelium (EN) from the anterior surface to the posterior surface of the cornea are clearly differentiated. Some of the superficial epithelial cells are detached, and a gap between the detected superficial cells and the remaining epithelial cells is observed. Figure 3 shows the representative images of a donor cornea in the regions of the epithelium and anterior stroma. FF-OCT images depicted in Figs. 3a, 3b, 3c, 3d, 3e, 3f, 3g were acquired at different depths indicated by the black arrows given in Fig. 3j, which was a reconstructed longitudinal cross section. To provide a better inspection of the depth information, Fig. 3j was expanded in the vertical direction by a factor of two. Figure 3a indicates the en face image at the level of wing cell layer, where a central dark area corresponds to a gap between the wing cell layers. Figure 3b was obtained just above a basement membrane, where a part of a thin basal epithelial nerve plexus running parallel to the basement membrane was observed. Figure 3c describes the FF-OCT image detected at a level of Bowman’s layer, where the outer bright ring possibly corresponds to a basement membrane located just above Bowman’s layer. This layer was an acellular layer, and no structural details were observed. The central highly scattering area in Fig. 3c was captured at the most anterior part of the stroma, revealing the uppermost stromal keratocytes. Figure 3d was detected at the region of underneath the uppermost stroma shown in Fig. 3c, where the uppermost layer of keratocyte spread out along Bowman’s layer. As observed in Fig. 3d, the nerve fibers (arrows) perforated Bowman’s layer and the most anterior stroma and went up through Bowman’s layer. Structurally, they were connected to the nerve plexus at the subbasal layer. Figures 3e, 3f, 3g, which were detected approximately , , and below Bowman’s layer, reveal the two-dimensional distributions of keratocytes at different depths. Keratocyte was seen as a flat cell connected by long cytoplasmic cell processes from their bodies, linked to adjacent keratocytes to form a network. The circularly arranged keratocytes and their interconnectivity were clearly observed in the FF-OCT images. For a better inspection, Figs. 3h and 3i show the three-times enlarged images of the dashed boxes in Figs. 3d and 3f, respectively. From the images, keratocyte nuclei, a portion of the cell body, and its projection appear bright. The images of Figs. 3d and 3g indicated that size of the keratocyte increased with depth as reported in the literature.25, 26 Nerve fibers are occasionally seen traversing the stroma, as indicated by an arrow in Fig. 3e. In the reconstructed longitudinal cross section shown in Fig. 3j, the Bowman’s layer appears as a dark band with a thickness of indicated by the two white arrows. The thin and curved layer oriented parallel to the corneal surface just above Bowman’s layer seems to correspond to the basement membrane. In the stroma, keratocytes were seen as a bright, slender profile parallel to the corneal surface. Intra-epithelial edema was observed at a level of the wing cell layer. Figure 4 reveals the FF-OCT imaging results at the regions of the posterior stroma and endothelium. Imaging was performed with the same sample and at the same transverse position as of Fig. 3. Figures 4a and 4b show the FF-OCT images at different depths, while 4e shows a reconstructed longitudinal cross section with arrows indicating the depths of the respective FF-OCT images. In Fig. 4e, the fold in Descemet’s membrane was observed as an arched structure and was projected toward the endothelial side. Figures 4a and 4b are FF-OCT images detected at the level of endothelium, showing the folds and the endothelial cells. Because of the higher axial resolution of FF-OCT and the curved structure of the endothelium cell layer, only a portion of the endothelial cells was observed in a single FF-OCT image. For a better inspection of the cells, Figs. 4c and 4d show the three-times enlarged images of the area indicated by the dashed boxes in 4a and 4b, respectively. Despite the presence of the folding, endothelium cells and their nuclei were visualized in both images. Finally, the imaging results of a donor cornea with a stroma’s scar were shown in Fig. 5 . Imaging was performed approximately apart from the center of the cornea. Figures 5a, 5b, 5c show three of the FF-OCT images acquired at different depths, while Fig. 5d shows the reconstructed longitudinal cross section indicated by the dashed line in Fig. 5a. The oval-shaped stromal scar was observed in the superficial stromal layer. Figure 5a showed the rupture of the basement membrane on the scar, while Figs. 5b and 5c revealed that the scar (arrows) lied across Bowman’s layer and the stroma. From the image shown in Fig. 5d, the scar appears to consist of densely packed slender keratocytes, and the size of the scar was estimated to be approximately in width and in depth. 4.Discussion4.1.Demonstration of a Superior Axial ResolutionIn a corneal confocal microscopy, the combination of a tightly focused beam and a conjugate pinhole placed in front of a single detector generally yields an axial resolution of and a transverse resolution of .23, 24, 27 By comparison, our FF-OCT system offers a significantly higher axial resolution of and a similar transverse resolution of . The result of Fig. 2 gives some evidence that the sectioning capability of our FF-OCT system using a low-cost halogen lamp is comparable to that of a conventional OCT using a state-of-the-art ultra-broadband femtosecond laser.28 In addition, FF-OCT provides an en face image that can delineate the morphological features of a human cornea at a subcellular level. Corneal epithelium, keratocytes in stroma, and endothelium were clearly observed. Epithelial edema between wing cell layers and the stroma’s scar in the superficial stromal layer were observed as well. It is noteworthy that corneal nerves were readily observed in the -plane. It has been well known from histology by scanning electron microscope that keratocytes have multiple long extensions and lie between the tightly packed collagen lamellaes that constitute the bulk of the stroma. The stroma has 200–250 layers of collagen lamellae. Assuming that the collagen lamellaes are evenly distributed across the stroma and that the thickness of the stroma is , the thickness of a collagen lamellae will be . Nevertheless, the thickness of the lamellae is not evenly distributed, where the anterior stroma has more densely packed thin lamellae than the posterior stroma.29 As such, the spatial resolution of FF-OCT in both axial and transverse directions may be suited for the imaging of 2D keratocyte distribution between collagen lamellaes. In the following, we examine the feasibility of FF-OCT for the visualization of a keratocyte network. The use of red and green pseudocolors is informative for displaying the depth dependence of keratocyte, where any colocalization will be observed as a different additive color when two individual FF-OCT images are merged into a single image. Figures 6a, 6b, 6c show three examples with different depth intervals of (a) , (b) , and (c) , respectively. All the images involved were acquired from the same measurement shown in Fig. 3. They were located approximately below Bowman’s layer, so that their en face planes were almost parallel to the collagen lamellae layer. The top layers in Figs. 6a, 6b, 6c are all identical, and they are colored red. In Fig. 6a where the depth interval is less than the axial resolution and the average thickness of the collagen lamellae layer, part of the keratocytes overlaps with each other and the overlapped area appears in yellow. On the other hand, in Fig. 6b, where the depth interval is slightly less than the axial resolution, the overlap seen in Fig. 6a gradually disappears. When the depth interval was increased to in Fig. 6c, that is, about equal to the average thickness of collagen lamellae, the individual keratocytes are mostly resolved. The result of Fig. 6 suggests that the thin layer sectioned out by FF-OCT may contain a single layer of keratocytes, provided that the imaging plane was almost parallel to the collagen lamellae. 4.2.Comparison with In Vivo Confocal MicroscopyThe axial resolution of FF-OCT is determined by the low coherence of the thermal light source, while that of the conventional confocal microscope is determined by the confocal parameter of the objective. Since FF-OCT offers a higher sensitivity than a confocal microscope,30 minute changes in corneal morphology can be detected with superior resolution. Both image contrasts are based on the intensity of backscattered light. However, the FF-OCT image is the result of the optical interference. Therefore, these two different imaging modalities may appear as different contrasts in the images detected. By integrating the ultrahigh-resolution FF-OCT images along the depth direction, it is possible to generate an en face image whose depth resolution is comparable to that of a conventional confocal image. Figure 7 shows such an example, where 7a and 7b are the integrations of two and three FF-OCT images, corresponding to a depth range of and , respectively. The images involved in the integrations were chosen from the measurement results that have been partially shown in Fig. 3, and they were acquired approximately underneath Bowman’s layer. It is observed in Figs. 7a and 7b that the keratocytes are tightly interconnected and the interpretation of their interconnection is complicated by the depth integration, in other words, the decreased resolving power of imaging. In contrast, Figs. 7c and 7d show the same integrations as those of 7a and 7b, but with depth information presented by pseudocolors of cyan, magenta, and yellow for the layers counted from the top to the bottom. An inspection of Figs. 7c and 7d shows that keratocytes are not spatially overlapped, a result that is consistent with the previous report by Muller 31 From the comparison in Fig. 7, it is apparent that FF-OCT with ultrahigh resolution in both axial and transverse directions is potentially valuable for the ex vivo study of 2D keratocyte network between collagen lamellaes. 4.3.System Limitation for In Vivo ImagingThere are some limitations in this study. Keratocyte is located between collagen lamellaes parallel to the corneal surface. To resolve a single layer of keratocyte, an incident parallel beam must be oriented normal to the corneal surface. Otherwise FF-OCT captures a slanted plane against the collagen lamellae. This precise positioning is easy for ex vivo imaging, but it is hard to achieve for in vivo imaging. In addition, image acquisition time is a critical issue for in vivo imaging. In the current system, image acquisition time is relatively lengthy , since a phase-shift operation and image averaging were employed to extract the interference component and to increase a detection sensitivity. Involuntary sample movement causes a degradation of the image quality, making an FF-OCT image low-contrast and blured. The sample must be immobile during measurement, so that the present system is only suited for ex vivo or in vitro study. For the purpose of in vivo imaging, an ultrahigh-speed FF-OCT system was demonstrated using a xenon arc flash lamp ( flashes).32, 33 Meanwhile, a video-rate FF-OCT system using a dual-channel detection scheme with a pair of CCD cameras is being developed in our laboratory.34 We are convinced that the current development of high-speed FF-OCT will lead to in vivo ultrahigh-resolution corneal imaging in the very near future. In conclusion, we have demonstrated the feasibility of ultrahigh-resolution FF-OCT for corneal imaging at a subcellular level. FF-OCT images of human donor corneas with an unprecedented axial resolution of and a transverse resolution of are presented. Our results provide experimental evidence that keratocytes existing between collagen lamellaes can be individually resolved by FF-OCT, which may lead to the visualization of the 3D keratocyte network. AcknowledgmentsThe authors thank Yasufumi Fukuma, Topcon Corporation, Japan, for providing helpful advice. The work by M. Akiba and K. P. Chan is partially supported by New Energy and Industrial Technology Development Organization (NEDO), Japan. ReferencesW. M. Bourne and
H. E. Kaufman,
“Specular microscopy of human corneal endothelium in vivo,”
Am. J. Ophthalmol., 81 319
–323
(1976). 0002-9394 Google Scholar
M. A. Lemp,
P. N. Dilly, and
A. Boyde,
“Tandem-scanning (confocal) microscopy of the full-thickness cornea,”
Cornea, 4 205
–209
(1986). 0277-3740 Google Scholar
H. D. Cavanagh,
W. M. Petroll,
H. Alizadeh,
Y. G. He,
J. P. McCulley, and
J. Y. Jester,
“Clinical and diagnostic use of in vivo confocal microscopy in patients with corneal disease,”
Ophthalmology, 100 1444
–1454
(1993). 0161-6420 Google Scholar
J. V. Jester,
T. Moller-Pedersen,
J. Huang,
C. M. Sax,
W. T. Kays,
H. D. Cavanagh,
W. M. Petroll, and
J. Piatigorsky,
“The cellular basis of corneal transparency: Evidence for ‘corneal crystallines’,”
J. Cell. Sci., 112 613
–622
(1999). 0021-9533 Google Scholar
M. Böhnke and
B. R. Masters,
“Confocal microscopy of the cornea,”
Prog. Retin Eye Res., 18 553
–628
(1999). 1350-9462 Google Scholar
I. Jalbert,
F. Stapleton,
E. Papas,
D. F. Sweeney, and
M. Coroneo,
“In vivo confocal microscopy of the human cornea,”
Br. J. Ophthamol., 87 225
–236
(2003). https://doi.org/10.1136/bjo.87.2.225 0007-1161 Google Scholar
J. A. Moilanen,
M. H. Vesaluoma,
L. J. Muller, and
T. M. Tervo,
“Long-term corneal morphology after PRK by in vivo confocal microscopy,”
Invest. Ophthalmol. Visual Sci., 44 1064
–1069
(2003). 0146-0404 Google Scholar
A. Eckard,
J. Stave, and
R. F. Guthoff,
“In vivo investigations of the corneal epithelium with the confocal rostock laser scanning microscope (RLSM),”
Cornea, 25 127
–131
(2006). 0277-3740 Google Scholar
D. Huang,
E. A. Swanson,
C. P. Lin,
J. S. Schuman,
W. G. Stinson,
W. Chang,
M. R. Hee,
T. Flotte,
K. Gregory,
C. A. Puliafito, and
J. G. Fujimoto,
“Optical coherence tomography,”
Science, 254 1178
–1181
(1991). https://doi.org/10.1126/science.1957169 0036-8075 Google Scholar
M. Wojtkowski,
Y. Srinivasan,
J. G. Fujimoto,
T. Ko,
J. S. Schuman,
A. Kowalczyk, and
J. S. Duker,
“Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography,”
Ophthalmology, 112 1734
–1746
(2005). https://doi.org/10.1016/j.ophtha.2005.05.023 0161-6420 Google Scholar
T. C. Chen,
B. Cense,
M. C. Pierce,
N. Nassif,
B. H. Park,
S. H. Yun,
B. R. White,
B. E. Bouma,
G. J. Tearney, and
J. F. de Boer,
“Spectral domain optical coherence tomography,”
Arch. Ophthalmol. (Chicago), 123 1715
–1720
(2005). 0003-9950 Google Scholar
M. A. Choma,
K. Hsu, and
J. A. Izatt,
“Swept source optical coherence tomography using an all-fiber ring laser source,”
J. Biomed. Opt., 10 044009
(2005). https://doi.org/10.1117/1.1961474 1083-3668 Google Scholar
Y. Yasuno,
V. Madjarova,
S. Makita,
M. Akiba,
A. Morosawa,
C. Chong,
T. Sakai,
K. P. Chan,
M. Itoh, and
T. Yatagai,
“Three-dimensional and high-speed swept-source optical coherence tomography for in vivo investigation of human anterior eye segments,”
Opt. Express, 13 10652
–10664
(2005). https://doi.org/10.1364/OPEX.13.010652 1094-4087 Google Scholar
W. Drexler,
“Ultrahigh-resolution optical coherence tomography,”
J. Biomed. Opt., 9 47
–74
(2004). https://doi.org/10.1117/1.1629679 1083-3668 Google Scholar
J. Rogers,
A. Podoleanu,
G. Dobre,
D. Jackson, and
F. Fitzke,
“Topography and volume measurements of the optic nerve using en-face optical coherence tomography,”
Opt. Express, 9 533
–545
(2001). 1094-4087 Google Scholar
L. Vabre,
A. Dubois, and
A. C. Boccara,
“Thermal-light full-field optical coherence tomography,”
Opt. Lett., 27 530
–532
(2002). 0146-9592 Google Scholar
M. Akiba,
K. P. Chan, and
N. Tanno,
“Full-field optical coherence tomography by two-dimensional heterodyne detection with a pair of CCD cameras,”
Opt. Lett., 28 816
–818
(2003). 0146-9592 Google Scholar
A. Dubois,
G. Moneron,
K. Grieve, and
A. C. Boccara,
“Three-dimensional cellular-level imaging using full-field optical coherence tomography,”
Phys. Med. Biol., 49 1227
–1234
(2004). https://doi.org/10.1088/0031-9155/49/7/010 0031-9155 Google Scholar
A. Dubois,
K. Grieve,
G. Moneron,
R. Lecaque,
L. Vabre, and
A. C. Boccara,
“Ultrahigh-resolution full-field optical coherence tomography,”
Appl. Opt., 43 2874
–2883
(2004). https://doi.org/10.1364/AO.43.002874 0003-6935 Google Scholar
W. Y. Oh,
B. E. Bouma,
N. Iftimia,
S. H. Yun,
R. Yelin, and
G. J. Tearney,
“Ultrahigh-resolution full-field optical coherence microscopy using camera,”
Opt. Express, 14 726
–735
(2006). https://doi.org/10.1364/OPEX.14.000726 1094-4087 Google Scholar
K. Grieve,
M. Paques,
A. Dubois,
J. Sahel,
C. Boccara, and
J. F. Le Gargasson,
“Ocular tissue imaging using ultrahigh-resolution, full-field optical coherence tomography,”
Invest. Ophthalmol. Visual Sci., 45 4126
–4131
(2004). 0146-0404 Google Scholar
K. Grieve,
A. Dubois,
M. Simonutti,
M. Paques,
J. Sahel,
J. Le Gargasson, and
C. Boccara,
“In vivo anterior segment imaging in the rat eye with high speed white light full-field optical coherence tomography,”
Opt. Express, 13 6286
–6295
(2005). https://doi.org/10.1364/OPEX.13.006286 1094-4087 Google Scholar
S. C. Kaufman,
D. C. Musch,
M. W. Belin,
E. J. Cohen,
D. M. Meisler,
W. J. Reinhart,
I. J. Udell, and
W. S. Van Meter,
“Confocal microscopy, a report by the American Academy of Ophthalmology,”
Ophthalmology, 111 396
–406
(2004). 0161-6420 Google Scholar
D. V. Patel and
C. N. McGhee,
“Mapping the corneal sub-basal nerve plexus in keratoconus by in vivo laser scanning confocal microscopy,”
Invest. Ophthalmol. Visual Sci., 47 1348
–1351
(2006). 0146-0404 Google Scholar
J. I. Prydal,
F. Franc,
P. N. Dilly,
M. G. Kerr Muir,
M. C. Corbett, and
J. Marshall,
“Keratocyte density and size in conscious humans by digital image analysis of confocal images,”
Eye, 12 337
–342
(1998). 0950-222X Google Scholar
C. Hahnel,
S. Somodi,
D. G. Weiss, and
R. F. Guthoff,
“The keratocyte network of human cornea: A three-dimensional study using confocal laser scanning fluorescence microscopy,”
Cornea, 19 185
–193
(2000). 0277-3740 Google Scholar
A. Labbe,
B. Dupas,
P. Hamard, and
C. Baudouin,
“In vivo confocal microscopy study of blebs after filtering surgery,”
Ophthalmology, 112 1979
–1986
(2005). 0161-6420 Google Scholar
W. Drexler,
U. Morgner,
R. K. Ghanta,
F. X. Kartner,
J. S. Schuman, and
J. G. Fujimoto,
“Ultrahigh-resolution ophthalmic optical coherence tomography,”
Nat. Med., 7 10
–15
(2001). 1078-8956 Google Scholar
Y. Komai and
T. Ushiki,
“The three-dimensional organization of collagen fibrils in the human cornea and sclera,”
Invest. Ophthalmol. Visual Sci., 32 2244
–2258
(1991). 0146-0404 Google Scholar
E. A. Swanson,
M. R. Hee,
G. J. Tearney,
B. E. Bouma,
S. A. Boppart,
J. A. Izatt,
J. G. Fujimoto,
M. E. Brezinski,
J. S. Shuman, and
C. A. Puliafito,
“Optical coherence tomography: Principles, instrumentation, and biological applications,”
Biomedical Optical Instrumentation and Laser-Assisted Biotechnology, Kluwer Academic Publishers, New York (1996). Google Scholar
L. J. Muller,
L. Pels, and
G. F. Vrensen,
“Novel aspects of the ultrastructural organization of human corneal keratocytes,”
Invest. Ophthalmol. Visual Sci., 36 2557
–2567
(1995). 0146-0404 Google Scholar
K. Grieve,
G. Moneron,
A. Dubois,
J.-F. Le Gargasson, and
A. C. Boccara,
“Ultrahigh resolution ocular microscopy using ultrashort acquisition time en face optical coherence tomography,”
J. Opt. A, Pure Appl. Opt., 7 368
–373
(2005). https://doi.org/10.1088/1464-4258/7/8/003 1464-4258 Google Scholar
G. Moneron,
A. C. Boccara, and
A. Dubois,
“Stroboscopic ultrahigh-resolution full-field optical coherence tomography,”
Opt. Lett., 30 1351
–1353
(2005). 0146-9592 Google Scholar
M. Akiba and
K. P. Chan,
“Real-time ultrahigh-resolution imaging by dual-channel full-field optical coherence tomography,”
(2007) Google Scholar
|