Open Access
26 September 2017 Dynamic in vivo imaging of small animal brain using pulsed laser diode-based photoacoustic tomography system
Author Affiliations +
Abstract
We demonstrate dynamic in vivo imaging using a low-cost portable pulsed laser diode (PLD)-based photoacoustic tomography system. The system takes advantage of an 803-nm PLD having high-repetition rate ∼7000  Hz combined with a fast-scanning single-element ultrasound transducer leading to a 5 s cross-sectional imaging. Cortical vasculature is imaged in scan time of 5 s with high signal-to-noise ratio ∼48. To examine the ability for dynamic imaging, we monitored the fast uptake and clearance process of indocyanine green in the rat brain. The system will find applications to study neurofunctional activities, characterization of pharmacokinetic, and biodistribution profiles in the development process of drugs or imaging agents.

1.

Introduction

Small animals are important models for preclinical studies and play a key role in guiding the study of human diseases and in seeking effective treatment. The ideal small animal imaging technique should provide noninvasive, high spatiotemporal resolution, deep penetration, anatomical and functional contrasts.1 The ability to directly visualize dynamics in small animal models at the full-body scale provides insights into biological processes at the whole-organism level. Optical imaging techniques suffer from either shallow penetration or a poor depth-to-resolution ratio; on the other hand, nonoptical imaging techniques for full-body imaging of small animals lack either spatiotemporal resolution or functional contrast.2,3

Photoacoustic tomography (PAT) is an emerging noninvasive, nonionizing, hybrid imaging modality that has found many demanding applications in both clinical and preclinical studies.4,5 PAT combines the advantages of both optical and ultrasound imaging modalities: high optical contrast and scalable ultrasound resolution and imaging depth. In PAT, short laser pulses (nanosecond) are absorbed by tissue chromophores and produce an acoustic wave [also known as photoacoustic (PA) wave]. Images are formed by reconstructing the PA signals acquired at various positions around the tissue. Over the past couple of decades, PAT has been successfully used for animal and human imaging. PAT has shown its potential for imaging various organs (heart, lungs, liver, eyes, spleen, brain, skin, spinal cord, kidney, etc.)6 in small animals. Multiple-wavelength PAT allows mapping of HbT—total hemoglobin concentration and SO2—oxygen saturation. PAT can provide information at molecular and genetic levels for better understanding of brain health.7 Photoacoustic microscopy (PAM) provides higher resolution imaging with sacrificed imaging depth and may also require scalp removal (minimally invasive).8 Whereas, PAT can provide few cm imaging depth, and it is a complete noninvasive technique. Therefore, PAT systems were widely used for whole filed brain imaging.9,10

A Q-switched Nd:YAG-pumped optical parametric oscillator is the most commonly used excitation sources for PAT, as they provide sufficient pulse energies (tens-millijoules) with 5  ns pulse widths at 10 to 100 Hz repetition rate. If single ultrasound transducer (UST) scanning is used, the temporal resolution of a Nd:YAG-based PAT system is limited by the low repetition rate of the laser and scanning/rotation speed of the UST. Typically, few minutes or longer are normally required to acquire one cross-sectional in vivo PAT image.11 A PAT system with such lengthy measurement time is not ideal for small animal imaging because it is difficult to control the physiological parameters for whole body imaging, time-resolved functional imaging, etc. Small animal neurofunctional imaging, oxygen saturation imaging, blood velocity imaging, etc. do require dynamic imaging capability. Monitoring the pharmacokinetic, circulation time of drugs/contrast agents is another important area where dynamic imaging is required.1214 If only one single-element UST is used to collect all the PA signals around the sample, it will limit the imaging speed of the system. Nd:YAG/PAT combined with multiple single-element USTs or array-bases USTs could achieve high-speed imaging. A multitransducer PAT was demonstrated based on the electrical slip ring.6 The lateral and axial resolution of the system was 0.129 and 1.49  mm, respectively. The scanning speed was 1.5 min/frame. In this system, electromagnetic shielding was a challenge for transmission of weak PA signals. A linear array-based PAT was demonstrated for full-view imaging.15 The imaging resolution was 60  μm, and the imaging speed was limited by the low repetition rate (20 Hz) of the laser and the slow manual rotation scan. A linear array-based PAT system was demonstrated for whole mouse brain imaging.16 Imaging resolution of the system was 70  μm and temporal resolution was 1 s. Several array-based USTs such as linear, semicircular, circular, and volumetric array are successfully used for real-time imaging.4 These array-based USTs will increase the imaging speed, but they are expensive, require custom made electronics, and will reduce the measurement sensitivity. Moreover, the imaging speed of a PAT system that uses array-based USTs is still limited by the repetition rate of the excitation laser.

Recently, pulsed laser diodes (PLDs) and light emitting diodes4,17,18 have been reported as compact and less expensive alternatives for Nd:YAG lasers. High-frame rate (7000 fps) B-scan PA imaging was shown with PLDs using clinical ultrasound platform.19 PLD with high-repetition rate can improve the imaging speed of a PAT system even with single-element UST circular scanning (CS) geometry. Single-element USTs are less expensive and highly sensitive unlike array-based USTs. Few research works were reported on using high-repetition rate PLDs as an excitation source for PA imaging. A fiber-based near infrared PLD was demonstrated for PA imaging on phantoms.20 In vivo imaging of blood vessels at 1-mm-depth below the human skin was demonstrated using low-energy PLDs.21 A PLD-based optical resolution photoacoustic microscopy (ORPAM) was reported. Using PLDs, 1.5-cm-deep imaging at a frame rate of 0.43 Hz was demonstrated.22 A low-cost photoacoustic computer tomography (LC-PACT) system was demonstrated for ex vivo imaging. The system uses 6 W 905-nm PLD, emitting 55 ns pulses at 20 kHz with 0.3 mJ pulse energy. The image of black tape acquired using LC-PACT in 30 s showed 5.4 dB signal-to-noise ratio (SNR).23 We reported a low-cost portable photoacoustic tomography (PLD-PAT) system for high-speed imaging.11,24 The system could provide hair phantom images in 3 s (with SNR 29 dB) and 30 s (with SNR 38 dB). The imaging speed and SNR of a PLD-PAT system in Ref. 11 are much higher than that presented in Ref. 23. In these letters, we report our studies of high-speed in vivo imaging on a small animal brain using a PLD-PAT system. We compare the in vivo brain images acquired at different scan speeds. To examine the high-speed, we monitored the fast uptake and clearance process of indocyanine green (ICG) in the cortical region of rat brain.

The schematic of the in vivo PLD-PAT imaging system is shown in Fig. 1. The PLD (Quantel, France) provides 136  ns pulses at 803  nm wavelength, and 1.4  mJ pulse energy (@ 7 kHz repetition rate). An optical diffuser (OD) was used to make the PLD beam more homogenous. The PLD was controlled by the laser driver (LD). The LD included a temperature controller (LaridTech, MTTC1410), a 12 V power supply (Voltcraft, PPS-11810), a variable power supply (BASETech, BT-153), and a function generator (FG250D, Funktionsgenerator). The function generator synchronizes data acquisition (DAQ) with the laser excitation. The animal brain and the UST were mounted as shown in Fig. 1. A cylindrically focused UST (V306-SU-NK-CF1.9IN Olympus NDT) of 2.25 MHz central frequency (70% fractional bandwidth), 13 mm active area, and focal length of 1.9 in. was used. The UST was driven by a step motor (SM) (Lin Engineering, Silverpak 23C) to circularly scan around the brain. The UST holder was mounted on a CS plate. The motion of the circular plate or UST was controlled by the computer-controlled SM. The UST detected signals were amplified, bandpass filtered by ultrasound signal receiver (A/F) unit (Olympus-NDT, 5072PR), and then digitized and recorded by the PC with DAQ card (25  Ms/s, GaGe, compuscope 4227).

Fig. 1

Schematic of the PLD-PAT system for in vivo small animal brain imaging: PLD, pulsed laser diode; OD, optical diffuser; CS, circular scanning plate; SMP, stepper motor pulley unit; UST, ultrasound transducer; A/F, amplifier/filter unit; LD, laser driver unit; SM, stepper motor; PC, personal computer; WT, water tank; DAQ, data acquisition card; AM, anesthesia machine; PM, transparent polythene membrane.

JBO_22_9_090501_f001.png

The maximum permissible exposure (MPE) limit for in vivo imaging is governed by the American National Standards Institute (ANSI). In the 700- to 1050-nm wavelength range, the energy density on the skin by single pulse should be <20×102(λ700)/1000  mJ/cm2 [λ(nm)].25 For 803-nm wavelength, the limit is 31  mJ/cm2. If laser is exposed continuously over a period of t=5  s, then the MPE becomes 1.1×102(λ700)/1000×t0.25  J/cm2 (=2.6  J/cm2). For in vivo imaging, the PLD was operated at 7000 Hz. In 5-s scan time, total 35000 (i.e., 5×7000) pulses were delivered to the sample, so per pulse the MPE is 0.074  mJ/cm2. The pulse energy was 1.4  mJ at laser window when the laser was operated at maximum power 10 W and repetition rate 7000 Hz. For in vivo imaging, pulse energy achieved on the tissue surface was 0.86  mJ distributed over 12-cm2 area. So, the energy density is 0.071  mJ/cm2 (0.86  mJ/12  cm2), which was within the ANSI limit 0.074  mJ/cm2 for 5 s scan time.

For in vivo animal experiments, NTac:Sprague Dawley®SD® female healthy rats of body weight 95±3  gm, procured from InVivos Pte. Ltd., Singapore, were used. Experiments were performed in accordance with the guidelines and regulations approved by the Institutional Animal Care and Use Committee of Nanyang Technological University, Singapore (ARF-SBS/NIE-A0263). The rat was anesthetized with a mixture of 2 ml of Ketamine (100  mg/ml), 2 ml of xylazine (20  mg/ml), and 1 ml of saline. Before going for imaging, the hair on the scalp was depilated. The animal was mounted in the system as shown in Fig. 1. A custom-designed animal holder was used to mount the animal. The animal was placed in sitting position, on its abdomen, and the body of the animal was secured to the mount with surgical tapes to provide grip for the animal. The mouth and nose of the animal were covered with a breathing mask to deliver anesthesia mixture during the experiment. The anesthesia was achieved by the continuous inhalation of a mixture of 1.0  L/min oxygen and 0.75% isoflurane. The animal brain was aligned to the center of the CS geometry. After completing the DAQ for imaging, the animal was euthanized by an intraperitoneal injection of pentobarbital of concentration 300  mg/ml.

We noninvasively imaged the brains of healthy rats using the high-speed in vivo PLD-PAT system. The rat was placed at the center of the laser illumination area and CS area. The A-lines signals from the rat brain area were acquired by continuously scanning the UST at predefined speed. Multiple PA signals were collected by the UST, the collected signals were preamplified with gain of 50 dB, and finally the amplified A-lines were saved once the rotation is complete. PA signals can be averaged later if needed. We acquired the PA signals from brain area in different scan times. The photograph of the brain taken before and after opening the scalp is shown in Figs. 2(a) and 2(b), respectively. An open scalp anatomical photograph of the cortex vasculature was taken after removing the scalp for comparison. PAT imaging was done noninvasively, i.e., with skin and skull intact. The reconstructed PAT cross-sectional images of the rat brain obtained by collecting PA signals in 30-, 20-, 10-, and 5-s scan time are shown in Figs. 2(c)2(f). Reconstruction was done using a simple delay-and-sum algorithm.26,27 In all the PAT cross-sectional images, the superior sagittal sinus (SS), transverse sinuses (TS), and cerebral veins (CV) of the rat brain are clearly visible. To study the effect of scan speed on the quality of the in vivo images, we calculated the SNR of images acquired at different scan speeds. The SNR was defined as the peak-to-peak amplitude of the PA signal divided by the standard deviation of the noise, SNR=V/n, where V is the peak-to-peak PA signal amplitude, and n is the standard deviation of the background noise. The SNR as a function of scan time is shown in Fig. 2(g). This experiment was done to compare the in vivo images at different scan speeds and to prove that even 5-s scanning time was enough to get high-quality brain images.

Fig. 2

Noninvasive images of brain vasculature in 95 gm female rat at different scan times: photograph of rat brain before (a) and after (b) removing the scalp. In vivo brain images at (c) 5-s, (d) 10-s, (e) 20-s, and (f) 30-s scan time. (g) SNR of in vivo images as a function of scan time. Here, SS, sagittal sinus; TS, transverse sinus; and CV, cerebral veins.

JBO_22_9_090501_f002.png

To examine the ability for high-speed brain imaging, ICG (12633-25mg, SigmaAldrich) was injected into the tail vein and the uptake and clearance of ICG were monitored by a PLD-PAT system in the vasculature of the brain dynamically. The photograph of the rat brain before and after opening the scalp is shown in Figs. 3(a) and 3(b), respectively. Before the administration of ICG, the cortical vascular structure was imaged noninvasively at 5-s scan time as shown in Fig. 3(c). To monitor the wash-in process of the dye, about 0.3 ml of ICG at 323  μM concentration was administered through tail vein injection.11 The entire cortical region was imaged at 5-s scan time. As shown in Fig. 3(c), the control image obtained before the injection has low contract. With the increase in the optical absorption by ICG at 803-nm wavelength, the vascular contrast started increasing, as shown in Figs. 3(d)3(f). The ICG dye in the blood vessels helped to recover fine vascular structures in the PA image at 803-nm wavelength. Figure 3(g) shows the measured increase and subsequent decrease in ICG signal in the superior SS over time. We observed same trend on multiple rats. This trend is similar to the one reported in Ref. 28. The uptake of ICG was maximum at 2-min postinjection and the clearance process of the dye was monitored for 25 min after injection. The increase in the PA values indicates the increase in the dye concentration within the cortex vessels. To generate the plot in Fig. 3(g), images were not acquired continuously. One PAT image in every 30  s or so was acquired, that means the laser was ON for 5 s and OFF for the rest 25 s.

Fig. 3

In vivo PLD-PAT brain imaging and pharmacokinetics of ICG intravenously injected in to rat brain: photograph of rat brain before (a) and after (b) removing the scalp. In vivo brain images at different scan times (c) 0 s, (d) 2 min, (e) 6 min, and (f) 13 min. (g) Graph shows the quantification of ICG signal in the superior SS during 25 min following injection. The red arrow indicates ICG injection point.

JBO_22_9_090501_f003.png

In this letter, we demonstrated an affordable and portable PLD-PAT system for high-speed and high-quality in vivo imaging on small animals. The potentiality of the system for dynamic in vivo imaging was demonstrated by monitoring a fast uptake and clearance process of ICG in the cortex vasculature. The in vivo brain images were acquired in scan time as short as 5 s with high SNR 48 using a single-element UST scanner. The temporal resolution can be improved using multiple UST and instead of rotating a full circle of 360 deg, one can rotate only 360/N deg (where, N is the number of USTs used). For example, if eight USTs are used, then imaging can be done at one frame per 0.5  s. The spatial resolution of the current PLD-PAT system is 384  μm (for 2.25 MHz transducer) and 185  μm (for 5 MHz transducers).11 The spatial resolution can be further improved using UST with higher central frequency and bandwidth. Although ring PA systems29 can provide real-time PA imaging, they are custom made and very expensive. The portability, low-cost, image quality promises that the proposed system will find applications in neurofunctional activities (such as epilepsy), characterization of pharmacokinetic, biodistribution profiles in the development process of drugs or imaging agents in small animal study.

Disclosures

Authors have no relevant financial interests in this work and no other potential conflicts of interest to disclose.

Acknowledgments

The authors would like to acknowledge the financial support from the Singapore Ministry of Health’s National Medical Research Council (NMRC/OFIRG/0005/2016: M4062012) and Ms. Vijitha Periyasamy for assisting in the animal experiments.

References

1. 

L. Li et al., “Single-impulse panoramic photoacoustic computed tomography of small-animal whole-body dynamics at high spatiotemporal resolution,” Nat. Biomed. Eng., 1 0071 (2017). http://dx.doi.org/10.1038/s41551-017-0071 Google Scholar

2. 

P. K. Upputuri et al., “Recent developments in vascular imaging techniques in tissue engineering and regenerative medicine,” BioMed Res. Int., 2015 1 –9 (2015). http://dx.doi.org/10.1155/2015/783983 Google Scholar

3. 

J. Xia and L. V. Wang, “Small-animal whole-body photoacoustic tomography: a review,” IEEE Trans. Biomed. Eng., 61 (5), 1380 –1389 (2014). http://dx.doi.org/10.1109/TBME.2013.2283507 IEBEAX 0018-9294 Google Scholar

4. 

P. K. Upputuri and M. Pramanik, “Recent advances toward preclinical and clinical translation of photoacoustic tomography: a review,” J. Biomed. Opt., 22 (4), 041006 (2017). http://dx.doi.org/10.1117/1.JBO.22.4.041006 JBOPFO 1083-3668 Google Scholar

5. 

L. V. Wang and S. Hu, “Photoacoustic tomography: in vivo imaging from organelles to organs,” Science, 335 (6075), 1458 –1462 (2012). http://dx.doi.org/10.1126/science.1216210 SCIEAS 0036-8075 Google Scholar

6. 

Z. Deng, W. Li and C. Li, “Slip-ring-based multi-transducer photoacoustic tomography system,” Opt. Lett., 41 (12), 2859 –2862 (2016). http://dx.doi.org/10.1364/OL.41.002859 OPLEDP 0146-9592 Google Scholar

7. 

J. J. Yao et al., “Noninvasive photoacoustic computed tomography of mouse brain metabolism in vivo,” NeuroImage, 64 (1), 257 –266 (2013). http://dx.doi.org/10.1016/j.neuroimage.2012.08.054 NEIMEF 1053-8119 Google Scholar

8. 

J. Yao et al., “High-speed label-free functional photoacoustic microscopy of mouse brain in action,” Nat. Methods, 12 (5), 407 –410 (2015). http://dx.doi.org/10.1038/nmeth.3336 1548-7091 Google Scholar

9. 

J. Yao, J. Xia and L. V. Wang, “Multiscale functional and molecular photoacoustic tomography,” Ultrason. Imaging, 38 (1), 44 –62 (2016). http://dx.doi.org/10.1177/0161734615584312 ULIMD4 0161-7346 Google Scholar

10. 

I. Olefir et al., “Hybrid multispectral optoacoustic and ultrasound tomography for morphological and physiological brain imaging,” J. Biomed. Opt., 21 (8), 086005 (2016). http://dx.doi.org/10.1117/1.JBO.21.8.086005 JBOPFO 1083-3668 Google Scholar

11. 

P. K. Upputuri and M. Pramanik, “Performance characterization of low-cost, high-speed, portable pulsed laser diode photoacoustic tomography (PLD-PAT) system,” Biomed. Opt. Express, 6 (10), 4118 –4129 (2015). http://dx.doi.org/10.1364/BOE.6.004118 BOEICL 2156-7085 Google Scholar

12. 

C. Xie et al., “Self-quenched semiconducting polymer nanoparticles for amplified in vivo photoacoustic imaging,” Biomaterials, 119 1 –8 (2017). http://dx.doi.org/10.1016/j.biomaterials.2016.12.004 BIMADU 0142-9612 Google Scholar

13. 

Y. Jiang et al., “Broadband absorbing semiconducting polymer nanoparticles for photoacoustic imaging in second near-infrared window,” Nano Lett., 17 (8), 4964 –4969 (2017). http://dx.doi.org/10.1021/acs.nanolett.7b02106 NALEFD 1530-6984 Google Scholar

14. 

A. Taruttis et al., “Fast multispectral optoacoustic tomography (MSOT) for dynamic imaging of pharmacokinetics and biodistribution in multiple organs,” PLoS One, 7 (1), e30491 (2012). http://dx.doi.org/10.1371/journal.pone.0030491 POLNCL 1932-6203 Google Scholar

15. 

G. Li et al., “Multiview Hilbert transformation for full-view photoacoustic computed tomography using a linear array,” J. Biomed. Opt., 20 (6), 066010 (2015). http://dx.doi.org/10.1117/1.JBO.20.6.066010 JBOPFO 1083-3668 Google Scholar

16. 

P. Zhang et al., “High-resolution deep functional imaging of the whole mouse brain by photoacoustic computed tomography in vivo,” J. Biophotonics, 1 –6 (2017). http://dx.doi.org/10.1002/jbio.201700024 Google Scholar

17. 

X. Dai, H. Yang and H. Jiang, “In vivo photoacoustic imaging of vasculature with a low-cost miniature light emitting diode excitation,” Opt. Lett., 42 (7), 1456 –1459 (2017). http://dx.doi.org/10.1364/OL.42.001456 OPLEDP 0146-9592 Google Scholar

18. 

J. T. Allen and C. P. Beard, “High power visible light emitting diodes as pulsed excitation sources for biomedical photoacoustics,” Biomed. Opt. Express, 7 (3), 1260 –1270 (2016). http://dx.doi.org/10.1364/BOE.7.001260 BOEICL 2156-7085 Google Scholar

19. 

K. Sivasubramanian and M. Pramanik, “High frame rate photoacoustic imaging at 7000 frames per second using clinical ultrasound system,” Biomed. Opt. Express, 7 (2), 312 –323 (2016). http://dx.doi.org/10.1364/BOE.7.000312 BOEICL 2156-7085 Google Scholar

20. 

J. S. Allen and P. Beard, “Pulsed near-infrared laser diode excitation system for biomedical photoacoustic imaging,” Opt. Lett., 31 (23), 3462 –3464 (2006). http://dx.doi.org/10.1364/OL.31.003462 OPLEDP 0146-9592 Google Scholar

21. 

R. G. M. Kolkman, W. Steenbergen and T. G. van Leeuwen, “In vivo photoacoustic imaging of blood vessels with a pulsed laser diode,” Lasers Med. Sci., 21 (3), 134 –139 (2006). http://dx.doi.org/10.1007/s10103-006-0384-z Google Scholar

22. 

K. Daoudi et al., “Handheld probe integrating laser diode and ultrasound transducer array for ultrasound/photoacoustic dual modality imaging,” Opt. Express, 22 (21), 26365 –26374 (2014). http://dx.doi.org/10.1364/OE.22.026365 OPEXFF 1094-4087 Google Scholar

23. 

A. Hariri et al., “Development of low-cost photoacoustic imaging systems using very low-energy pulsed laser diodes,” J. Biomed. Opt., 22 (7), 075001 (2017). http://dx.doi.org/10.1117/1.JBO.22.7.075001 JBOPFO 1083-3668 Google Scholar

24. 

P. K. Upputuri and M. Pramanik, “Pulsed laser diode based optoacoustic imaging of biological tissues,” Biomed. Phys. Eng. Express, 1 (4), 045010 (2015). http://dx.doi.org/10.1088/2057-1976/1/4/045010 Google Scholar

25. 

American National Standard for Safe Use of Lasers, Laser Institute of America, New York (2000). Google Scholar

26. 

S. K. Kalva and M. Pramanik, “Experimental validation of tangential resolution improvement in photoacoustic tomography using a modified delay-and-sum reconstruction algorithm,” J. Biomed. Opt., 21 (8), 086011 (2016). http://dx.doi.org/10.1117/1.JBO.21.8.086011 JBOPFO 1083-3668 Google Scholar

27. 

M. Pramanik, “Improving tangential resolution with a modified delay-and-sum reconstruction algorithm in photoacoustic and thermoacoustic tomography,” J. Opt. Soc. Am. A, 31 (3), 621 –627 (2014). http://dx.doi.org/10.1364/JOSAA.31.000621 JOAOD6 0740-3232 Google Scholar

28. 

N. C. Burton et al., “Multispectral opto-acoustic tomography (MSOT) of the brain and glioblastoma characterization,” NeuroImage, 65 (2), 522 –528 (2013). http://dx.doi.org/10.1016/j.neuroimage.2012.09.053 NEIMEF 1053-8119 Google Scholar

29. 

C. Li et al., “Real-time photoacoustic tomography of cortical hemodynamics in small animals,” J. Biomed. Opt., 15 (1), 010509 (2010). http://dx.doi.org/10.1117/1.3302807 JBOPFO 1083-3668 Google Scholar
© 2017 Society of Photo-Optical Instrumentation Engineers (SPIE) 1083-3668/2017/$25.00 © 2017 SPIE
Paul Kumar Upputuri and Manojit Pramanik "Dynamic in vivo imaging of small animal brain using pulsed laser diode-based photoacoustic tomography system," Journal of Biomedical Optics 22(9), 090501 (26 September 2017). https://doi.org/10.1117/1.JBO.22.9.090501
Received: 16 June 2017; Accepted: 5 September 2017; Published: 26 September 2017
Lens.org Logo
CITATIONS
Cited by 58 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Imaging systems

Brain

In vivo imaging

Neuroimaging

Acquisition tracking and pointing

Signal to noise ratio

Photoacoustic tomography

Back to Top