Paper
12 March 2020 3-D flame chemiluminescence tomography imaging under limited projection angle conditions: constraints and improving
Author Affiliations +
Abstract
The main challenge and limitation of combustion diagnosis technique lies in the volumetric/spatial resolution. Frequently reported technique widely use laser bean scanning to get inner knowledge of combustion, however due to the line-of-sight nature, spatial resolution along the “path” is lacked. With the ability of 3-D tomography detection, CTC technique (computed tomography of chemiluminescence) shows advantage over other techniques; but not yet widely used in combustion science study. In CTC measurement, “dense projection” is required to make satisfying tomography reconstruction, but this is practically hard to meet for high cost and spatial limitation. At sparse projection conditions, tomography reconstruction is distorted with the appearance of geometric blur. The reason of occurrence of blur is analyzed in this paper, and an improved method for tomography reconstruction is proposed. Test results show that blur distortion could be effectively eliminated using the improved method at sparse projection conditions. Other factors and constraints that have influence on flame tomography measurement are discussed in this paper, and quantitative evaluations were made through tests.
© (2020) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yanting Cheng, Feng Chi, Jianjun Wang, Qiang Jing, and Rujun Song "3-D flame chemiluminescence tomography imaging under limited projection angle conditions: constraints and improving", Proc. SPIE 11434, 2019 International Conference on Optical Instruments and Technology: Optical Systems and Modern Optoelectronic Instruments, 114340Z (12 March 2020); https://doi.org/10.1117/12.2548769
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Tomography

Chemiluminescence

Combustion

3D image processing

Optical tomography

Optical testing

Oxidation