29 August 2022 Packaging design and test of cryogenic readout electronics for the Euclid Near Infrared Spectrophotometer
W. Holmes, H. Aghakians, S. Avasapian, A. Bahraman, A. Berg, A. Beyer, E. Boehmer, R. Calvet, S. Cheung, B. Cho, H. Cho, A. Cillis, L. DelCastillo, M. Dickie, G. Delo, M. Farris, A. Feizi, N. Ferraro, L. Fischer, R. Foltz, N. Hambarsoumian, K. Hong, T. Huang, M. Jhabvala, Er. Kan, R. Kopp, B. Krohn, D. Lewis, M. Loose, K. MacNeal, J. Maiten, D. Markley, G. Maldonado, J. Mehta, J. Melendez, A. R. Morgan, J. Mulder, M. Ngyuen, N. Ovee, M. Pniel, S. Pravdo, D. Randall, J. Riendeau, A. Runkle, M. Runyan, M. Seiffert, M. Skalare, P. Tan, A. Turner, S. Van Nostrand, A. Waczynski, J. Wu
Author Affiliations +
Abstract
We describe the design of the cryogenic packaging and testing of the Sensor Chip Electronics (SCE) delivered to the Near-Infrared Spectro-Photometer (NISP) instrument for the ESA Euclid mission. The Euclid mission will observe 15 000 deg2 of extragalactic sky1 from the Sun{Earth Lagrange point L2. The payload of the Euclid spacecraft consists of a telescope with 1.2m SiC primary mirror, passively cooled to ~ 125 K, and two focal plane instruments, the visible instrument (VIS) and NISP. At the heart of the NISP instrument is a 4 x 4 mosaic focal plane of Teledyne H2RG infrared detector arrays held at 100K linked using a cryogenic ex cable (CFC) to the SCE at as low as 130 K. The SCE uses the Teledyne SIDECAR Application Specific Integrated Circuit (ASIC) to provide timing, biases, communications, and data conversion for operation of the HAWAII 2 RG (H2RG) Sensor Chip Assembly (SCA) and interfaces to the NISP warm electronics. The SIDECAR ASIC is mounted onto a Silicon Fanout (SiFO) and Invar table support structure and then wirebonded to a printed wiring board assembly (PWB) with passive components and 91-pin nanoconnectors. The PWB is housed within an enclosure which serves as the mechanical and thermal interface to the NISP Support Structure. The qualification and flight SCE were assembled and subjected to environmental testing at the Jet Propulsion Laboratory and then calibrated and tested with the flight lot SCA and CFC at Goddard Space Flight Centers Detector Characterization Lab. The results of the qualification and reliability tests as well as the measured characteristics of the flight SCE will be summarized.
Conference Presentation
© (2022) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
W. Holmes, H. Aghakians, S. Avasapian, A. Bahraman, A. Berg, A. Beyer, E. Boehmer, R. Calvet, S. Cheung, B. Cho, H. Cho, A. Cillis, L. DelCastillo, M. Dickie, G. Delo, M. Farris, A. Feizi, N. Ferraro, L. Fischer, R. Foltz, N. Hambarsoumian, K. Hong, T. Huang, M. Jhabvala, Er. Kan, R. Kopp, B. Krohn, D. Lewis, M. Loose, K. MacNeal, J. Maiten, D. Markley, G. Maldonado, J. Mehta, J. Melendez, A. R. Morgan, J. Mulder, M. Ngyuen, N. Ovee, M. Pniel, S. Pravdo, D. Randall, J. Riendeau, A. Runkle, M. Runyan, M. Seiffert, M. Skalare, P. Tan, A. Turner, S. Van Nostrand, A. Waczynski, and J. Wu "Packaging design and test of cryogenic readout electronics for the Euclid Near Infrared Spectrophotometer", Proc. SPIE 12191, X-Ray, Optical, and Infrared Detectors for Astronomy X, 121911U (29 August 2022); https://doi.org/10.1117/12.2629611
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cryogenics

Electronics

Reliability

Aluminum

Silicon

Interfaces

Packaging

Back to Top