Paper
19 May 2008 An IntenCD map of a reticle as a feed-forward input to DoseMapper
Michael Ben Yishai, Jo Finders, Robert Kazinczi, Arno Bleeker, Paul Luehrmann, Ingrid Janssen, Frank Duray, Lior Shoval, Christophe Couderc, Rich Piech, Noam Hillel, Ilan Englard
Author Affiliations +
Abstract
The tight process window of advanced lithography in the semiconductor industry is further challenged by the growing contribution of photo-mask related CD variations. In previous technology generations, global measurement and global correction were sufficient to compensate for critical dimension uniformity (CDU) variations deriving from various sources. However, in the low K1 regime for 45nm nodes and below, cross-coupled effects such as Mask Error Enhancement Factor (MEEF) and mask CDU can easily consume the overall CD budget related to lithographic process steps (see table 3). ASML's DoseMapper was designed to correct system (e.g. scanner, track) and non-system (e.g. mask) related errors controlled by an Automated Process Control (APC) system. It was introduced as a method for correcting intra-field and inter-field variations, relying on feedback from printed wafer based metrology. Here we propose using AMAT's IntenCDTM map for supplying dense CDU measurement results from the reticle as a feed-forward input to DoseMapper. The IntenCDTM application characterizes CD uniformity of 'features of interest' across the mask in the form of a dense map with high accuracy and throughput. The case studies presented in this paper are the result of collaboration between AMAT and ASML to demonstrate the benefit of feeding IntenCD output into DoseMapper CD analyzer which translates the mask CD map into a scanner dose recipe. The integrated solution can be implemented in manufacturing factories to shorten turnaround time and improve the exposure process window. It can be used to compensate for CDU effects due to mask production as well as contributions due to life time deterioration.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Michael Ben Yishai, Jo Finders, Robert Kazinczi, Arno Bleeker, Paul Luehrmann, Ingrid Janssen, Frank Duray, Lior Shoval, Christophe Couderc, Rich Piech, Noam Hillel, and Ilan Englard "An IntenCD map of a reticle as a feed-forward input to DoseMapper", Proc. SPIE 7028, Photomask and Next-Generation Lithography Mask Technology XV, 70283H (19 May 2008); https://doi.org/10.1117/12.793124
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications and 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Photomasks

Critical dimension metrology

Semiconducting wafers

Reticles

Scanners

Metrology

Lithography

Back to Top