1 July 2009 Extraction of residual stress and dimensions from electrical measurements on surface micromachined test structures
Author Affiliations +
Abstract
The deposited thin films in surface micromachining have a lot of residual stress, and it is essential to measure this for both process development and monitoring. We estimate residual stress by electrical measurements on a series of fixed-fixed polysilicon beams designed to deflect laterally due to stress. To minimize errors in estimation during parameter extraction, the device dimensions also have to be measured accurately. Surface micromachining of an oxide-anchored polysilicon cantilever beam can result in beam undercut, reduction in beam thickness, and increase in the gap between the beam and the substrate. The undercut in the beam is estimated from the resonance frequency of the cantilever beam and also by using polysilicon resistors. Final device thickness is obtained by measuring the resistance in fixed-fixed beams.
©(2009) Society of Photo-Optical Instrumentation Engineers (SPIE)
Somashekara Bhat and Enakshi Bhattacharya "Extraction of residual stress and dimensions from electrical measurements on surface micromachined test structures," Journal of Micro/Nanolithography, MEMS, and MOEMS 8(3), 031309 (1 July 2009). https://doi.org/10.1117/1.3167825
Published: 1 July 2009
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Resistors

Resistance

Oxides

Etching

Surface micromachining

Reactive ion etching

Thin films

RELATED CONTENT

PMMA deep etching by O2RIE
Proceedings of SPIE (November 29 2000)
Electrical measurement of undercut in surface micromachining
Proceedings of SPIE (February 18 2008)
Integrated mold/surface-micromachining process
Proceedings of SPIE (May 20 1996)
Fabrication of TiNi shape memory actuator for micropump
Proceedings of SPIE (September 29 1999)

Back to Top